title: "Targeted Drip Leg Improvements Reduce Steam Loss and Strengthen System Reliability"
description: "When a large U.S. refinery began planning for additional compressor capacity, field data revealed the real problem wasn’t a lack of equipment—it was air loss. "
type: article
version: 1
version_id: "7f15d65a-993b-4219-964c-4b1c28964b23"
generated_at: "2026-09-21T18:59:33.189Z"
author: "addressing excess condensate"
date_published: "2026-09-01T17:30:27.000Z"
date_modified: "2026-09-02T19:37:40.850Z"
language: en
reading_time: "2 min"
word_count: 350
url: "https://www.hydrusworks.com/resources/better-data-turns-capital-spend-into-maintenance-with-air-leak-study-clone"
---

# Targeted Drip Leg Improvements Reduce Steam Loss and Strengthen System Reliability

> When a large U.S. refinery began planning for additional compressor capacity, field data revealed the real problem wasn’t a lack of equipment—it was air loss.

## Key Takeaways

- Targeted Drip Leg Improvements Reduce Steam Loss and Strengthen System Reliability

        Steam Survey Reveals Hidden System Losses
- Targeted Drip Leg Improvements Reduce Steam Loss and Strengthen System Reliability

        Steam Survey Reveals Hidden System Losses

# Targeted Drip Leg Improvements Reduce Steam Loss and Strengthen System Reliability

# Steam Survey Reveals Hidden System Losses

When a large chemical manufacturing facility experienced excessive condensate across its steam system, a site-wide drip leg survey uncovered hidden losses affecting equipment performance and reliability. The survey identified 90 plugged drip legs and an estimated $114,000 in annual steam losses, giving the facility clear opportunities for corrective action. By addressing excess condensate, the site reduced stress on critical equipment and improved overall system efficiency. Download the case study to see how targeted steam system improvements reduced operating costs and supported long-term reliability.

[Download Case Study](https://www.hydrusworks.com/hubfs/Hydrus%20Works%20Drip%20Leg%20Survey%20Case%20History%20\(2\).pdf)

---

## About This Content

**Source:** [Targeted Drip Leg Improvements Reduce Steam Loss and Strengthen System Reliability](https://www.hydrusworks.com/resources/better-data-turns-capital-spend-into-maintenance-with-air-leak-study-clone)
**Author:** addressing excess condensate
**Published:** September 1, 2026

*This content is provided for informational purposes. Please visit the original source for the most up-to-date information.*